skip to main content

King County Department of Assessments

Setting values, serving the community, and promoting fairness and equity.

Department of Assessments

201 South Jackson Street,
Seattle, WA 98104

Office Hours:
Mon - Fri
8:30 a.m. to 4:30 p.m.

TEL: 206-296-7300
TTY relay: 711 or 800-833-4388

Send us mail

 
PARCEL DATA
Parcel068780-0000
Name 
Site Address2716 ELLIOTT AVE 98121
Geo Area 30-90
Spec Area 700-10
Property NameBELLORA CONDOMINIUM
JurisdictionSEATTLE
Levy Code0011
Property Type K
Plat Block / Building Number
Plat Lot / Unit Number
Quarter-Section-Township-Range NW-31-25-4
Legal Description

PLat Block:
Plat Lot:


LAND DATA
  Click the camera to see more pictures.
Picture
Highest & Best Use As If VacantMULTI-FAMILY DWELLING
Highest & Best Use As ImprovedPRESENT USE
Present UseCondominium(Mixed Use)
Land SqFt14,389
Acres0.33
Percentage Unusable100
UnbuildableNO
Restrictive Size ShapeNO
ZoningDMR/C 145/75
WaterWATER DISTRICT
Sewer/SepticPUBLIC
Road AccessPUBLIC
ParkingADEQUATE
Street SurfacePAVED
Views Waterfront
Rainier
Territorial
Olympics
Cascades
Seattle Skyline
Puget Sound
Lake Washington
Lake Sammamish
Lake/River/Creek
Other View
Waterfront Location
Waterfront Footage0
Lot Depth Factor0
Waterfront Bank
Tide/Shore
Waterfront Restricted Access
Waterfront Access RightsNO
Poor QualityNO
Proximity InfluenceNO
Designations Nuisances
Historic Site
Current Use(none)
Nbr Bldg Sites 
Adjacent to Golf FairwayNO
Adjacent to GreenbeltNO
Other DesignationNO
Deed RestrictionsNO
Development Rights PurchasedNO
EasementsNO
Native Growth Protection EasementNO
DNR LeaseNO
 
Topography
Traffic Noise
Airport Noise 
Power LinesNO
Other NuisancesNO
Problems
Water ProblemsNO
Transportation ConcurrencyNO
Other ProblemsNO
Environmental
EnvironmentalNO

BUILDING
Building Number1
Building DescriptionBELLORA CONDOMINIUM
Number Of Buildings Aggregated1
Predominant UseAPARTMENT (300)
ShapeVery Irreg
Construction ClassREINFORCED CONCRETE
Building QualityGOOD
Stories13
Building Gross Sq Ft4,707
Building Net Sq Ft4,707
Year Built2003
Eff. Year2003
Percentage Complete100
Heating SystemCOMPLETE HVAC
SprinklersYes
ElevatorsYes
Section(s) Of Building Number: 1
Section NumberSection UseDescriptionStoriesHeightFloor NumberGross Sq FtNet Sq Ft
4 RETAIL STORE (353)0040112118263263
2 RETAIL STORE (353)0020 retail/living twnhs with 0060112101559559
6 RETAIL STORE (353)0070 retail/living twnhs with 0030112201985985
1 RETAIL STORE (353)00101121001,2841,284
3 RETAIL STORE (353)0060- retail/living twnhs with 0020112102981981
5 RETAIL STORE (353)0030 retail/living twnhs with 0070112200635635


Apartment / Condo Complex Data 
Complex TypeMixed Res and Cml Condo
Complex Description86 Residential, 7 Commercial
Value Distribution MethodPcnt Land Val
# of Bldgs1
# of Stories13
# of Units93
Avg Unit Size589
Land Per Unit155
Project LocationAVERAGE
Project AppealABOVE AVERAGE
% With View0
Construction ClassREINFORCED CONCRETE
Building QualityGOOD
ConditionAverage
Year Built2003
Eff Year2003
% Complete100
ElevatorsY
Security SystemY
FirePlaceY
LaundryPRIVATE
Kitchens
# of Meals0
Founder's Fee
Apt ConversionN
Condo Land TypeFee Simple






TAX ROLL HISTORY


SALES HISTORY


REVIEW HISTORY


PERMIT HISTORY

Permit NumberPermit DescriptionTypeIssue DatePermit ValueIssuing JurisdictionReviewed Date
7156294-EL Adding switches fans and outlets and replacing a sub panel[8/18/2026 JBC Added (12) 15-30amp Circuits to Permit],  8/3/2026$0SEATTLE 
7147783-EL Installing 7.2 kW Level 2 30A EV charger on 30A branch circuit with local disconnect,  6/11/2026$0SEATTLE 
7146537-EL Branch circuit,  6/5/2026$0SEATTLE 
7132568-CN Construct alterations to unit #1000 in existing mixed use building, per plan., Remodel4/15/2026$10,000SEATTLE 
7138220-CN STFI - interior remodel (finishes), no structural or exterior work, Remodel4/14/2026$75,000SEATTLE 
7119890-EL Add 1 Fire alarm module to Nitrogen compressor for the fire sprinkler system,  12/5/2025$1,000SEATTLE 
7115134-EL Adding 120v to avc-6 from the ECS Wall mount generator.[11/26/2025 JBC Added (1) 20amp & (1) 30amp Circuit to the Permit),  11/4/2025$1,400SEATTLE 
7099061-EL New car charger Adding 2 outlets 2 cans Swapping some dimmers,  7/30/2025$4,000SEATTLE11/7/2025
7053230-EL 1x lighting circuit,  10/25/2024$1,403SEATTLE11/7/2025
6991771-EL Upgrading aging Lutron lighting panel and lighting controls with new Lutron Homeworks QSX system.,  10/18/2023$35,000SEATTLE11/7/2025
6896974-CN Construct alterations to existing multifamily building to convert units 303 and 304 into one unit, occupy per plan., Remodel10/5/2022$0SEATTLE11/7/2025
6893403-CN Interior alterations to bathroom in unit 602 at existing multi-family building, subject to field inspection (STFI), Remodel5/20/2022$25,423SEATTLE11/7/2025
6887109-CN Remodel bathroom for condominium unit 201, subject to field inspection., Remodel3/9/2022$10,000SEATTLE11/7/2025
6826471-CN Add partition wall and door to existing Live/Work unit, subject to field inspection [STFI]., Remodel3/4/2021$500SEATTLE11/7/2025
6625772-CN Construct glass roof additions and alterations to roof deck of existing 13th floor penthouse unit PH-01, replace hot tub, per plans. ", "", ", Remodel6/11/2018$150,000SEATTLE9/29/2020
6555837 Construct interior to multifamily condominium unit 303 subject to field inspection STFI, Remodel9/9/2016$150,000SEATTLE9/29/2020

HOME IMPROVEMENT EXEMPTION